Search results for "width [Lambda(1405)]"
showing 10 items of 330 documents
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…
FLUMO: FLexible Underwater MOdem
2019
The last years have seen a growing interest in underwater acoustic communications because of its applications in marine research, oceanography, marine commercial operations, the offshore oil industry and defense. High-speed communication in the underwater acoustic channel has been challenging because of limited bandwidth, extended multipath, refractive properties of the medium, severe fading, rapid time variation and large Doppler shifts. In this paper, we show an implementation of a flexible Software-Defined Acoustic (SDA) underwater modem, where modulation parameters are completely tunable to optimize performance. In particular, we develop the system architecture following two key ideas. …
All polarization-maintaining assively mode-locked yb-doped fiber laser : pulse compression using an anomalous polarization-maintaining photonic cryst…
2019
We report the generation of short pulses at 1 μm using an all-polarization-maintaining (PM) fiber configuration. The pulses are provided by an all normal-dispersion Fabry-Perot Yb-doped cavity and are compressed with an anomalous polarization-maintaining photonic crystal fiber (PM PCF). Opposed to standard configurations; here the filtering action is solely performed by the finite bandwidth of the gain medium. The laser generates 8 ps width sech 2 profile pulses at 1046.8 nm with a −10 dB bandwidth of 5.9 nm. After compression using the PM PCF, pulses with an FWHM of 3 ps were obtained, limited by the actual value of the available anomalous dispersion. We also report the changes in the outp…
Enabling Searches on Wavelengths in a Hyperspectral Indices Database
2018
Abstract. Spectral indices derived from hyperspectral reflectance measurements are powerful tools to estimate physical parameters in a non-destructive and precise way for several fields of applications, among others vegetation health analysis, coastal and deep water constituents, geology, and atmosphere composition. In the last years, several micro-hyperspectral sensors have appeared, with both full-frame and push-broom acquisition technologies, while in the near future several hyperspectral spaceborne missions are planned to be launched. This is fostering the use of hyperspectral data in basic and applied research causing a large number of spectral indices to be defined and used in various…
A new tool for sepsis screening in the Emergency Department
2021
Abstract Objectives In this study, we developed and evaluated the diagnostic accuracy of the Sepsis Index for early sepsis screening in the Emergency Department (ED). Methods Sepsis Index is based on the combination of monocyte distribution width (MDW) and mean monocyte volume (MMV). Sepsis Index≥1 was selected to define sepsis. We tested its diagnostic accuracy in an ED population stratified in four groups: controls, Systemic Inflammatory Response Syndrome (SIRS), infection, and sepsis, according to Sepsis-2 criteria. Results Patients with sepsis displayed higher median Sepsis Index value than patients without sepsis. At the receiver operating characterictis (ROC) curve analysis for the pr…
Design and Performance Evaluation of a High Power-Density EMI Filter for PWM Inverter-Fed Induction-Motor Drives
2016
This paper presents the design of an electromagnetic interference (EMI) filter for a low-voltage high-current induction-motor drives supplied by dc power grids. In order to effectively design the EMI filter, a suitable common-mode/differential-mode (CM/DM) separation technique has been used. Due to the high operating currents, the software-based separation technique using time-domain measurements has been applied. The proposed technique allows the CM and DM sections of the EMI filter to be properly selected in a more economical way, i.e., without the need of a dedicated hardware or costly radio frequency (RF) instrumentation. The design has been done according to a power-density criterion. …
Thermal noise limit for ultra-high vacuum noncontact atomic force microscopy
2013
The noise of the frequency-shift signal Δf in noncontact atomic force microscopy (NC-AFM) consists of cantilever thermal noise, tip–surface-interaction noise and instrumental noise from the detection and signal processing systems. We investigate how the displacement-noise spectral density dz at the input of the frequency demodulator propagates to the frequency-shift-noise spectral density dΔf at the demodulator output in dependence of cantilever properties and settings of the signal processing electronics in the limit of a negligible tip–surface interaction and a measurement under ultrahigh-vacuum conditions. For a quantification of the noise figures, we calibrate the cantilever displacemen…
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…
A Channel-Aware Adaptive Modem for Underwater Acoustic Communications
2021
Acoustic underwater channels are very challenging, because of limited bandwidth, long propagation delays, extended multipath, severe attenuation, rapid time variation and large Doppler shifts. A plethora of underwater communication techniques have been developed for dealing with such a complexity, mostly tailoring specific applications scenarios which can not be considered as one-size-fits-all solutions. Indeed, the design of environment-specific solutions is especially critical for modulations with high spectral efficiency, which are very sensitive to channel characteristics. In this paper, we design and implement a software-defined modem able to dynamically estimate the acoustic channel c…